Product Introduction
Sample Information:
Sample Description: Polyester/Spandex Inherent Flame Retardant Knitted Fabric (Black)
Test Standard:
The test was conducted according to DIN 4102-1:1998 Fire Behavior of Building Materials and Elements, Part 1: Classification of Building Materials Requirements and Testing.
Test Results:
DIN 4102-1:1998 B1 Requirement:
Test Method: The test was performed using the ‘Brandschacht’ apparatus specified in DIN 4102-16.
Sample Size: 190mm x 1000mm
Parameters:
Parameter
Test Result
Requirement
Minimum remaining length of burning
≥ 0 cm
Average remaining length of burning
≥ 1 cm
Maximum average flue gas temperature
≤ 200°C
DIN 53438: Small Flame Ignition Test:
Sample Details:
Edge Ignition: 5 pieces, 90mm x 190mm
Surface Ignition: 5 pieces, 90mm x 230mm
Conditioning:
Temperature: 23 ± 2°C
Relative Humidity: 50 ± 5%
Duration: 24 hours
Test Results:
Ignition Type
Sample No.
Flaming Reached Gauge Mark within 20 Seconds (Yes/No)
Edge Ignition
Surface Ignition
Conclusion:
The tested sample meets the DIN 4102-1 B1 requirement for fire behavior of building materials, which classifies it as flame retardant. The sample successfully passed both the DIN 4102-16 test using the ‘Brandschacht’ apparatus and the DIN 53438 small flame ignition test.