Product Introduction
Test Report Summary: BS7175 Ignitability Test for Bedcovers and Pillows
Sample Description: Inherent Flame Retardant Duvets (24*24)
Color: White
Composition: Polyester
Test Requested: BS 7175:1989 – Methods of Test for Ignitability of Bedcovers and Pillows by Smouldering and Flaming Ignition Sources, Section 2
Conclusion: Non-ignition (NI) for all test specimens under Ignition Source 7 (Crib 7).
Test Details
Sample Description: Duvet
Sample Size: 650mm x 650mm
Conditioning: Specimens and cribs were conditioned for 72 hours in ambient conditions, then for at least 16 hours at 20±5℃ and 65±5% humidity.
Test Results
Ignition Source Position (a: Upper Surface, b: Beneath Overhang 100mm):
Test No.
Ignition Source
Progressive Smouldering (PS)
Flaming (F)
Duration of Ignition Source (min)
Duration of Flames (min)
Duration of Smoke (min)
Extent of Damage (Length, mm)
1st (a)
Crib 7
2nd (a)
Crib 7
1st (b)
Crib 7
2nd (b)
Crib 7
Observations
Progressive Smouldering: No
Flaming: No
Final Examination of Smouldering: None
Test Result: Non-Ignition (NI) for all specimens
Photo Appendix: SGS authenticated the photo on the original report.